Article designation (table-figure)
| Add to request
| Nominal diameter, DN (mm)
| Nominal pressure, Р (MPa)
| Operating medium
| Operating medium temp., °С, not more than
| Body details material
| Dimensions, mm
| Control method (electric actuator type)
| Valve class and group under ОТТ-87
| Medium leakage in closure, cm3/min, not more than
| Abutting pipe Дн хS, mm
| Installation place
| Weight, kg, not more than
| H
| H1
| H2
| h
| h1
| h2
| h3
| L
| I
| У26161-020М1
| 
| 20
| 1,0
| Primary coolant, steam-gas mixture, steam, distillate, multiple forced circulation circuit water, cooling water of protection management system circuit, acids, alcali, blow-off gases, air, nitrogen, neutral gases, desactivation and washing solutions, oils, waters of bridging boards.
| 200
| 08Х18Н10Т
| 245
| 263
| 510
| 35
| 175
| 168
| 440
| 160
| 120
| Manual
| 2ВIIв, 2ВIIIс, 3СIIIв, 3СIIIс
| 0,36
| 25х3
| Under cover and out of cover
| 8,2
| -01
| 
| For joint coupling
| -02
| 
| Electric actuator М76371-С1536D203
| 36,2
| -03-О
| 
| Electric actuator 2-ОМ-21-КМ3
| Under cover
| 24,7
| -03-П
| 
| Electric actuator 2-ПМ-21-КМ3
| Out of cover
| -04
| 
| Oils, steam, condensate, feed water, air, nitrogen, neutral gases, desactivation and washing solutions, process water (chlorides content up to 300 mg/l, oxygen - up to 20 mg/l)
| Steel 20
| Manual
| 25х2
| Under cover and out of cover
| 8,2
| -05
| 
| For joint coupling
| -06
| 
| Electric actuator М76371-С1536D203
| 36,2
| -07-О
| 
| Electric actuator 2-ОМ-21-КМ3
| Under cover
| 24,7
| -07-П
| 
| Electric actuator 2-ПМ-21-КМ3
| Out of cover
|
| Article designation (table-figure)
| Add to request
| Nominal diameter, DN, mm
| Nominal pressure, Р, MPa
| Operating medium
| Operating medium temp., 0С, not more than
| Body details material
| Dimensions, mm
| Control method (electric actuator type)
| Valve class and group under ОТТ-87
| Medium leakage in closure, cm3/min, not more than
| Abutting pipe Дн хS, mm
| Installation place
| Weight, kg, not more than
| H
| H1
| H2
| h
| h1
| h2
| h3
| L
| I
| У26161-020М1-08
| 
| 20
| 2,5
| Primary coolant, steam-gas mixture, steam, distillate, multiple forced circulation circuit water, cooling water of protection management system circuit, acids, alcali, blow-off gases, air, nitrogen, neutral gases, desactivation and washing solutions, oils, waters of bridging boards.
| 250
| 08Х18Н10Т
| 245
| 263
| 510
| 35
| 175
| 168
| 440
| 160
| 120
| Manual
| 2ВIIв, 2ВIIIс, 3СIIIв, 3СIIIс
| 0,36
| 25х3
| Under cover and out of cover
| 8,2
| -09
| 
| For joint coupling
| -10
| 
| Electric actuator М76371-С1536D203
| 36,2
| -11-О
| 
| Electric actuator 2-ОМ-21-КМ3
| Under cover
| 24,7
| -11-П
| 
| Electric actuator 2-ПМ-21-КМ3
| Out of cover
| -12
| 
| Oils, steam, condensate, feed water, air, nitrogen, neutral gases, desactivation and washing solutions, process water (chlorides content up to 300 mg/l, oxygen - up to 20 mg/l)
| Steel 20
| Manual
| 25х2
| Under cover and out of cover
| 8,2
| -13
| 
| For joint coupling
| -14
| 
| Electric actuator М76371-С1536D203
| 36,2
| -15-О
| 
| Electric actuator 2-ОМ-21-КМ3
| Under cover
| 24,7
| -15-П
| 
| Electric actuator 2-ПМ-21-КМ3
| Out of cover
|
|
|