Article designation (table-figure)

Add to request

Nominal diameter, DN, mm

Nominal pressure, Р, MPa

Operating medium

Operating medium temp., 0С, not more than

Body details material

Dimensions, mm

Control method (electric actuator type)

Valve class and group under ОТТ-87

Medium leakage in closure, cm3/min, not more than

Abutting pipe
Дн хS, mm

Installation place

Weight, kg, not more than

H

H1

H2

h

h1

h2

h3

L

I

У26161-065М1

Add to cart

65

1,0

Primary coolant, steam-gas mixture, steam, distillate, multiple forced circulation circuit water, cooling water of protection management system circuit, acids, alcali, blow-off gases, air, nitrogen, neutral gases, desactivation and washing solutions, oils, waters of bridging boards.

200

08Х18Н10Т

362

394

684

85

273

219

544

340

260

Manual

2ВIIв, 2ВIIIс, 3СIIIв, 3СIIIс

1,2

76х4,5

Under cover and out of cover

37,5

-01

Add to cart

For joint coupling

36,5

-02

Add to cart

Electric actuator М76371-С1531Е203

75,0

-03-О

Add to cart

Electric actuator 2-ОА-34-КМ3

69,0

-03-П

Add to cart

Electric actuator 2-ПА-34-КМ3

Out of cover

-04

Add to cart

Oil, steam, condensate, feed water, air, neutral gases, desactivation and washing solutions, process water (chloride content up to 300 mg/l, oxygen up to 20 mg/l)

Steel 20

Manual

76х3

Under cover and out of cover

37,5

-05

Add to cart

For joint coupling

36,5

-06

Add to cart

Electric actuator М76371-С1531Е203

75,0

-07-О

Add to cart

Electric actuator 2-ОА-34-КМ3

69,0

-07-П

Add to cart

Electric actuator 2-ПА-34-КМ3

Out of cover

Article designation (table-figure)

Add to request

Nominal diameter, DN, mm

Nominal pressure, Р, MPa

Operating medium

Operating medium temp., 0С, not more than

Body details material

Dimensions, mm

Control method (electric actuator type)

Valve class and group under ОТТ-87

Medium leakage in closure, cm3/min, not more than

Abutting pipe
Дн хS, mm

Installation place

Weight, kg, not more than

H

H1

H2

h

h1

h2

h3

L

I

У26161-065М1-08

Add to cart

65

2,5

Primary coolant, steam-gas mixture, steam, distillate, multiple forced circulation circuit water, cooling water of protection management system circuit, acids, alcali, blow-off gases, air, nitrogen, neutral gases, desactivation and washing solutions, oils, waters of bridging boards.

250

08Х18Н10Т

362

394

684

85

273

219

544

340

260

Manual

2ВIIв, 2ВIIIс, 3СIIIв, 3СIIIс

1,2

76х4,5

Under cover and out of cover

37,5

-09

Add to cart

For joint coupling

36,5

-10

Add to cart

Electric actuator М76371-С1531Е203

75,0

-11-О

Add to cart

Electric actuator 2-ОА-34-КМ3

69,0

-11-П

Add to cart

Electric actuator 2-ПА-34-КМ3

Out of cover

-12

Add to cart

Oil, steam, condensate, feed water, air, neutral gases, desactivation and washing solutions, process water (chloride content up to 300 mg/l, oxygen up to 20 mg/l)

Steel 20

Manual

76х3

Under cover and out of cover

37,5

-13

Add to cart

For joint coupling

36,5

-14

Add to cart

Electric actuator М76371-С1531Е203

75,0

-15-О

Add to cart

Electric actuator 2-ОА-34-КМ3

69,0

-15-П

Add to cart

Electric actuator 2-ПА-34-КМ3

Out of cover